>>>Links: User Summary of Two Years Decoration and Loss
A. Finding solutions to wall problems <br> If you have already considered using latex paint for wall decoration, you must understand some basic knowledge and know how to find solutions when you encounter the following problems.
First, the wall cracking: This phenomenon is the most common, the specific reasons for the situation may be, if it is GRC lightweight partitions, then the joints should be carefully done anti-crack treatment, generally with glass cloth or kraft paper, partition board Its characteristics are easy to appear small cracks, so the family decoration in order to ensure that the occurrence of cracking phenomenon is best to fully paste the glass fiber cloth or bean bag cloth, such as bearing walls or solid walls, cracking may be due to construction of putty is too thick or short interval of putty In this case, there are many cases where the old house is rebuilt to level out.
Second, the wall flowers, uneven color: the main color is not the same grassroots, there is no treatment, this situation must be filled with scraping putty or brush to cover it again. In addition, the selection of materials should pay attention to selecting the same manufacturer, the same variety and the same lot number, otherwise there will be color difference three, the surface roughness: the main reason is that the grassroots processing is not clean, the brush has sand, debris or * for the environment is not clean. Preventive measures include grassroots clean handling, brush cleaning, and environmental protection.
Fourth, from the skin: The main reason is that the base is too smooth or oily, preventive measures with a steel brush bristles to the grass and clean, oil with solvent for decontamination.
B. Frequently Asked Questions about Ground Construction <br> I. Empty Deck on the Floor of a Facing Tile (I) Phenomenon After the laying of marble, granite, tile, and other facing bricks, tap the empty drum with a small hammer to make sounds. Loose bricks.
(b) Reasons
1. The grassroots dries up, the watering wets not enough, causes the cement mortar to lose the water quickly, the bond strength of the brick and the mortar reduces; The cement mortar or the adhesive paving or the brushing takes too long, the mud air-drys, cannot have the adhesive effect.
2. The mortar did not add much, and the bonding layer did not work.
3. The grass-roots treatment is not clean or the prefabricated bricks are not soaked in wet or un-removed bricks on the back of the bricks before construction. The dried bricks quickly absorb the moisture in the cement mortar, resulting in dehydration of the mortar and affecting the setting hardening.
4. When the construction is not full of mortar to form an empty drum, or the mortar is too thick, and the hammering is too heavy, the mortar sinks, the water floats, and the adhesive strength of the mortar weakens.
5. After the mortar solidified, the brick removal was corrected.
(III) Measures 1. Treat the grass-roots level as required, and do not collect water when watering the wet ground.
2. When using cement mortar, cement mortar is best dry mortar. With 425 cement, the ratio of cement to sand is 1:2 to 4.
3. The tile is soaked in water before laying to remove surface floating soil.
4. Strictly according to construction specifications*.
Second, the veneer panel joints uneven, uneven gap (a) phenomenon Marble, granite, tile and other decorative stone tiles laying, the adjacent plate uneven, uneven width.
(b) Cause 1. Strict purchase and selection of plates, plate thickness, size error, warping, skew and other defects.
2. There was no attention to leveling and lengthening the cable when paving.
3. The cement mortar or glue is pressed during the coagulation process to loosen the binding layer of the cement mortar or the adhesive and the facing brick.
(III) Measures 1. The purchase and selection of plates must be strict and reject unqualified.
2. According to the provisions of the construction, at any time with the level and ruler leveling, the gap to lengthen the cable.
3. Do not tread before condensation.
Third, there is a sound of walking on the wooden floor (a) phenomenon to walk on the wood floor, wooden floor sound.
(b) Cause 1. Wooden keel or wool floor is not firmly installed.
2. Wooden keels or wood floors have low moisture content, shrink after drying and cause loosening.
3. The wood floor is not firmly installed.
(III) Measures 1. Strictly control the quality of wood, especially the moisture content, and prevent it from being soaked in water after entering the site.
2. Wooden keels are firmly installed according to regulations.
3. Wooden floor Nails stick firmly. After nailing and sticking inspection at any time and place, does not meet the requirements of timely repairs.
Fourth, the wooden floor surface is not smooth, local warping drum (a) phenomenon The surface of the wooden floor is not flat, local drum or partial tilt.
(b) Cause 1. Wood is deformed by moisture.
2. There is no moisture-proof layer on the wet ground, and wood floors are directly laid, and the wooden floor is damp.
3. During the construction, the depth of the projectile is not allowed. When the plane is leveled, the mast is not straight.
4. The wood floor is not firmly installed.
5. When the floor leveling day, shaved uneven.
(III) Measures 1. Prevent wood from getting damp.
2. Wet floors were covered with high wood flooring and a moisture barrier must be provided.
3. Correct the horizontal line before laying the floor and surface floor, and adjust the error in time.
4. Wooden floor nails stick firmly.
5. Correctly use it as a planer to master the technique of manual netting.
C. Frequently Asked Questions about Ceiling Construction <br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><br><
(b) Cause 1. The elevation of the ceiling was not identified, or the line was not clear, and the local elevation was wrong.
2. The ceiling spacing is too large and the keel deforms too much.
3. Wooden keel ceiling wood moisture content, shrinkage deformation.
4. When using wood screws, the distance between the screws and the edge of the gypsum board is inconsistent.
(III) Measures 1. The water column method is used to find the elevation line around the wall. The bullet line is clear and the position is accurate.
2. Light steel keel boom spacing should be 1200 ~ 1500 mm, not too large.
3. The wood used meets the requirements and is firmly fixed.
4. The distance between the screw and the edge of the board or the end of the board must not be less than 10 mm, nor more than 16 mm. The middle screw of the plate must not be more than 200 mm apart.
Second, the paper plaster ceiling cracks (a) phenomenon of gypsum board ceiling paper, after a period of time, gypsum board joints cracks.
(b) Cause 1. The structure of the slot joints is not reasonable.
2. Gypsum board quality is poor, expansion and contraction deformation.
3. Caulking putty quality is poor.
4. Improper construction measures.
5. Ceiling keel is not fixed.
D. Five Essentials of Rows of Wires When decorating a dark wire, you need to grasp the following five points:
—— Before construction, fully consider the electrical and lighting equipment required for each functional area, and use this as a basis to roughly calculate the cross-sectional area of ​​the corresponding wire for each road. High-quality copper core sheathed cables and concealed junction boxes should be used as far as possible to avoid aging and breaking, resulting in difficulty in panel installation.
- Draw the distribution diagrams of various residential circuits, and set the coordinates and heights of various lamps, switches, sockets, and distribution boards to determine the alignment of the routes and branches. The wires are best chosen in different colors in order to identify different circuits. |.cn (63639032)
- It is best to lay the power cord after it is put through the flame retardant pipe. In the ceiling of flammable structures, fire-retardant pipe must be added, and a power switch should be provided outside the ceiling to cut off the power supply when necessary. All wire connections should be inside the junction box.
- The total capacity of the indoor lines should not exceed 3000 watts per minute, and the load current of each single-phase circuit should not exceed 15 amps. Air conditioners and other large household appliances should set up special lines.
——The installation height of the switch is generally 1,200-13,050 mm from the ground, the height of the socket is generally 200-300 mm, and the height of the switchboard is preferably 1800-2000 mm.
E. Frequently Asked Questions about Doors and Windows Installation 1. Overall Stiffness of Doors and Windows Frames (1) Phenomenon Pushing or opening or closing doors or windows or encountering windy weather, door and window frames are shaking.
(b) Reasons
1. Improper selection of profiles, small sections, and insufficient strength. The prevention of aluminum alloy door and window materials does not meet the requirements. Plastic steel door and window material quality failed.
2. The lining steel configuration of the steel doors and windows does not conform to the standard, and the steel walls are thin and of poor strength; the lining steel is inserted in sections, which does not form an integral reinforcing effect; the lining steel and plastic profiles are not firmly connected.
3. The installation node is not in accordance with the specification.
4. There are no different fixing methods depending on the wall.
(III) Measures 1. The specifications and quantity of door and window frame profiles conform to national standards. The thickness of the outer frame of the aluminum alloy profile shall not be less than 2.4 mm. Plastic window material thickness should not be less than 2.5 mm.
2. Check the appearance of plastic profiles. Qualified profiles should be white or ivory white, clean and smooth. Better quality protective film.
3. According to the size of doors and windows and installation height, profile section should be selected. Casement window is not less than 55 series, and sliding window is not less than 75 series.
4. In strict accordance with the provisions of the provisions of the installation, to ensure solid and stable.
Second, the door and window leakage (a) phenomenon
1. Leakage between the door frame and the surrounding wall.
2. Sliding window sinks into the tank and seeps into the window.
(b) Reasons
1. Door and window frames and walls are cemented with cement mortar.
2. The gap between the window frame and the wall is not strict and there is a gap.
3. The door and window process failed, and the window frame and the window sash did not combine.
4. The sash seals were not installed and water penetrated through the sash glass gap.
5. The window frame has no drainage holes.
(III) Measures 1. Door and window frames and walls shall not be caulked with cement mortar. Should be flexible connection, sealed with sealant, no gaps.
2. Before the installation, check whether the doors and windows are qualified, whether the combination between the window frame and the sash is strict, and whether the sash sealing strip is installed is qualified.
3. There is more than 50 mm gap between the window frame and the hole to make the window sill able to make the water flow slope.
4. The bottom frame of the frame and the orbital root should be drilled.
Third, the color difference of doors and windows is obvious (I) Phenomenon: The colors of adjacent windows, doors or windows and windows are inconsistent.
(b) Cause The material is not the same factory product, or the same batch of products, or products of different material grades.
(III) Measures 1. You should use the same manufacturer's products for the selected profiles, and prepare them once at a time.
2. Pay attention to the color of the ingredients before cutting, and avoid using materials with large color difference in the same door and window.
Experience talk window cement glass switch paint floor tile glass brick glass door craft glass
Steel Grating is Steel plate bearing flat steel and rail in accordance with certain spacing were studied by orthogonal design, by welding or pressure lock to be fixed to the open type steel member; bar commonly used after twisted steel, also can use steel or flat steel, the material is divided into stainless steel and carbon steel. Lattice steel plate mainly used for steel structure platform board, ditch cover, steel ladder step plate, ceiling and other buildings.Steel plate has been widely used in all walks of life at home and abroad, mainly used for industrial platform, handrail, stair treads, channel floor, railway bridge side road, high altitude platforms, drainage ditch cover, manhole cover, road fence, parking lot, offices, schools, factories, enterprises and institutions, sports field, the Les Loges Du Park Hotel outside the fence, the window can also be used as a residential balcony guardrail, highway, railway guardrail etc..
Steel Grating
Steel Grating,Steel Driveway Grates Grating,Stainless Steel Floor Grating,Catwalk Steel Grating