How to solve the common faults of electronic patrol?

1, stainless steel waterproof patrol fault processing:

1) Inspector does not work

First check whether the battery is in poor contact. Otherwise, the battery power may be insufficient and the battery needs to be charged.
If you ignore the low-voltage indication and continue to use it, it will be fully discharged and the inspector will stop working.

Charging requires a longer charging time than usual when fully discharged.

After the above steps, it still cannot be charged or the patrol meter still cannot be used normally. Please contact the supplier.
Note: The patrol meter data will not be lost after full discharge. The battery is strongly impacted, which may result in damage to the battery and may not work properly.

2) Cannot confirm the data transmission cable works normally

Make sure the data transmission cable is connected to the computer and data patrol.

If the computer is using a communication port between the Internet or a PC, port conflicts may occur. At this time, select other ports through the parameter settings in the system management.

Possible exceptions when using the prompt function:

Content Reason Display Measures

Low voltage warning Low battery voltage Please charge immediately Refill after use

The data is too full. The data is too full. Please download after download.

Wrong time or abnormal data. Incorrect operation. Can be reset by computer. Use the correct method for the inspection (power on first, and then the proximity card)

Can't boot Battery contact is bad Contact between battery and host contacts

The light is not on The battery voltage is too low The light does not display Use the battery before recharging

2, RF-2200 series color screen Chinese inspection device troubleshooting:

a, do not show
1) First, check if the battery contacts are in poor contact. Otherwise, the battery power may be insufficient and the battery needs to be charged.
2) If you ignore the low voltage instruction and continue to use it, it will be fully discharged and the patrol unit will stop working.
3) In the case of full discharge, charging takes longer than usual.

b, can not communicate:
1), can not confirm the data transmission cable is working properly
2) Confirm that the data transmission cable is connected to the computer and data inspection device.
3) If the computer is using a communication port between the Internet or a PC, port conflicts may occur. At this point select other ports through the port settings in the system.