Learn how to start the motor with Dalan


The main problem faced when starting the motor is that the starting current is relatively large, and sometimes the starting torque is controlled. The appropriate starting method must be adopted. Common oil pump motor starting methods include: full pressure direct start, auto-decompression start, star-delta conversion Start, soft starter, frequency converter. The following is a detailed analysis of several different startup methods by Da Lan Motor Xiaobian:

1, full pressure direct start:

In the case of full-voltage direct start in both grid capacity and load, full-voltage direct start can be considered. The advantages are convenient operation control, simple maintenance and economical. It is mainly used for the starting of small power motors. From the perspective of saving electric energy, this method should not be used for motors larger than 11kw.

2, auto-decompression start:

The multi-tap decompression of the autotransformer can not only meet the needs of different load starting, but also obtain a larger starting torque. It is a decompression starting method that is often used to start a large capacity motor. Its biggest advantage is that the starting torque is large. When its winding tap is at 80%, the starting torque can reach 64% of the direct starting. And the starting torque can be adjusted by tapping. It is still widely used today.

3, star triangle start:

For a squirrel-cage asynchronous motor whose normal running stator winding is delta-connected, if the stator winding is connected to a star at the start, and then connected to the triangle after the start, the starting current can be reduced and the grid can be reduced. The impact. Such a starting method is called a star-delta decompression starting, or simply a star-delta starting (y-δ starting). When starting with the star-delta, the starting current is only 1/3 of the original starting directly by the delta connection. If the starting current at the time of direct start is 6 to 7 ies, the starting current is only 2 to 2.3 times at the start of the star-delta. This means that when starting with the star-delta, the starting torque is also reduced to 1/3 of the original starting directly by the delta connection. Suitable for applications with no load or light load start. And compared with any other decompression starter, its structure is the simplest and the cheapest. In addition, the star-delta starting method has the advantage that when the load is light, the motor can be operated in star connection. At this time, the rated torque can be matched with the load, which can improve the efficiency of the motor and save power consumption.

4, soft starter:

This is the use of the phase shift voltage regulation principle of the thyristor to achieve the voltage regulation start of the motor, mainly used for the start control of the motor, the starting effect is good but the cost is high. Due to the use of thyristor components, the thyristor has a large harmonic interference during operation and has a certain impact on the power grid. In addition, fluctuations in the power grid can also affect the conduction of the thyristor components, especially when there are multiple thyristor devices in the same power grid. Therefore, the failure rate of the thyristor component is high, and since the power electronics technology is involved, the requirements for the maintenance technician are also high.

5, the inverter:

The frequency converter is the motor control device with the highest technical content, the most complete control function and the best control effect in the field of modern motor control. It adjusts the speed and torque of the motor by changing the frequency of the power grid. Because it involves power electronics technology and microcomputer technology, it is costly and has high requirements for maintenance technicians. Therefore, it is mainly used in areas where speed regulation is required and speed control is required.










----- Editor-in-Chief: Dalan Oil Pump Motor 02-Procurement Consultant

Copyright http: / (Dalan Motor) Reprint, please indicate the source
Http://news.chinawj.com.cn

QUARTER ROUND

Name : QUARTER ROUND Vinyl flooring (spc flooring,click spc flooring)
Board Thickness : 4.0-7.0mm
Wearing Layer Thickness :0.3mm,0.5mm as regular
Surface Texture :Deep Grain,Wood Grain,Marble Grain,Stone,Carpet
Finish :UV-Coating
Installation :Click system(Unilin,Valinge)
Delivery Time :15-25 days
Size:6''*48''(150mm*1220mm)
7''*48''(182mm*1220mm)
9''*48''(230mm*1220mm)
9''*60''(230mm*1525mm)
Backing Foam :IXPE(1.0mm,1.5mm,2.0mm) EVA(1.0mm,1.5mm)
Density :2.07kg/m3
Surface :Wood Embossed,Deep Wood Embossed,Handscraped,Eir.
Usage :Bedroom,Kitchen,Basements,Home,School,Hospital,Mall,Commercial to use.
Features :Waterproof,Wear resistant,Anti-slip,Moisture Proof,Fireproof,durable, anti-scratch, anti-bacterail.

Market :Export to American,Canadian,European Market,Part Asia,Africa Countries.Australia Market

Warranty :10 years for commercial and 25 years for residential

Stone Plastic Composite vinyl flooring is more and more popular new style eco-friendly vinyl flooring. SPC rigid flooring is set apart from other types of vinyl flooring by its uniquely resilient core layer. This core is made from a combination of natural limestone powder, polyvinyl chloride and some stabilizers.
SPC vinyl is a luxury vinyl flooring option with a structurally rigid, 100% waterproof core. SPC is also known as rigid core vinyl, and we use these terms interchangeably. Rigid core engineered vinyl flooring is designed to look like wood or stone, but requires less upkeep.
This flooring is durable, waterproof, and perfect for DIY installation. It`s ideal for both home and commercial areas.

QUARTER ROUND,PVC QUARTER ROUND,SPC QUARTER ROUND,WPC QUARTER ROUND

JIANGSU PERFECT NEW MATERIAL TECHNOLOGY CO., LTD. , https://www.bffloor.com