Tube Expanding Tool CT-300A/M
Â
Expanding range | Â Diameter16-28mm |
Tonnage | 5 ton |
Weight | 4 kg |
Dies |
(CT-300A)Inch: 3/8", 1/2", 5/8", 3/4", 7/8", 1", 1-1/8" O.D. Tubing. (CT-300M)Metric: 10, 12, 16, 19, 22, 25, 28mm O.D. Tubing. |
Package | plastic box |
Weight of box | approx 1.0kg |
1. Material:Â Aluminum alloy body
Â
2. Use: Used for soft copper tube,alumimum tube,titanium tube,soft steel and other soft tube.
Â
3.Dvantages:
- No copper coupling needed any more,Save cost of material.
- Only one side need to be welded.Save cost and reduce possibility of leak.
- Manual hydraulic mechanism design can expand tubings from 10mm to 42mm diameterÂ
5.Use CT-300P for the spare expander head below 28mm and CT-300PL for up 28mm.
6.Packed in hand carrying plastic case
Six Easy steps:
1 de burr inside of tube.
2 anneal the tube if necessary(for hard or thickwall tube).
3 screw the expander head on expander.
4 put the end of tube on expander head.
5 tighten the relief valve knob to 'On' position then pump handle until tubeÂ
is expanded to the end.
5Turn the relief valve knob to 'OFF' position to loosen expander head.Â
remove expanded tube.
Â
Tube Expanding Tool CT-300A/M
Â
Expanding range | Â Diameter16-28mm |
Tonnage | 5 ton |
Weight | 4 kg |
Dies |
(CT-300A)Inch: 3/8", 1/2", 5/8", 3/4", 7/8", 1", 1-1/8" O.D. Tubing. (CT-300M)Metric: 10, 12, 16, 19, 22, 25, 28mm O.D. Tubing. |
Package | plastic box |
Weight of box | approx 1.0kg |
1. Material:Â Aluminum alloy body
Â
2. Use: Used for soft copper tube,alumimum tube,titanium tube,soft steel and other soft tube.
Â
3.Dvantages:
- No copper coupling needed any more,Save cost of material.
- Only one side need to be welded.Save cost and reduce possibility of leak.
- Manual hydraulic mechanism design can expand tubings from 10mm to 42mm diameterÂ
5.Use CT-300P for the spare expander head below 28mm and CT-300PL for up 28mm.
6.Packed in hand carrying plastic case
Six Easy steps:
1 de burr inside of tube.
2 anneal the tube if necessary(for hard or thickwall tube).
3 screw the expander head on expander.
4 put the end of tube on expander head.
5 tighten the relief valve knob to 'On' position then pump handle until tubeÂ
is expanded to the end.
5Turn the relief valve knob to 'OFF' position to loosen expander head.Â
remove expanded tube.
Â
Human Monkeypox Virus (MPV) Antigen Rapid Test Device (colloidal gold) is an in vitro diagnostic test for the qualitative detection of human monkeypox virus antigens in Nasopharyngeal swab,saliva and exudate of blain using the rapid immunochromatographic method. The identification is based on the monoclonal antibodies specific for the human monkeypox virus antigen. It will provide information for clinical doctors to prescribe correct medications.
monkeypox virus test,monkeypox virus,virus monkeypox,monkey poxs,monkey pox
Yong Yue Medical Technology(Kunshan) Co.,Ltd , https://www.yongyuecultureplate.com